Record the empty-container discharge as individual dumps. An hourly average can conceal a brief pile-up at the receiver. Obtain the unit count and elapsed time of each dump, then measure the downstream device’s accepted output during and after it. Ask the integrator to confirm the usable buffer under the intended operating conditions.
Compare the dump with the available buffer
In an illustrative run, 540 bottles enter during a 45-second discharge. If 90 leave in that window, 450 accumulate. A buffer of 320 positions, empty at the start, leaves a gap of 130 bottles. At a verified 120 bottles per minute afterward, clearing 450 bottles would take 3.75 minutes if output stays stable and no more arrive.
| Observation | Example | Decision |
|---|---|---|
| Bottles released in one dump | 540 in 45 seconds | Confirm demand on the receiver |
| Accepted during that window | 90 | Use the actual downstream count |
| Backlog and usable space | 450 against 320 free spaces | Review dump size or buffer design |
| Recovery before next dump | 3.75 minutes at 120 per minute | Verify with a witnessed trial |
Review accumulation and rate balance on a PET line
Assess the receiver against the discharge profile
Send actual bottles per dump, frequency, buffer dimensions and observed downstream output.